DC Series/RFI Power Line Filters for DC Applications
Place of Origin: |
Shanghai, China (Mainland) |
Product Detail
Model No.:
DC Series (15-125 Amp)
Certification:
UL Recognized CSA Certifie...
General purpose line filtersfor DC applications up to 125VDC
Available with or without acircuit breaker
DC Series
- General purpose line filtersfor DC applications up to 125VDC
- Available with or without acircuit breaker
- Available with feedthroughcapacitors for added high
frequency performance - Available in both flange mound(DCF) and
bulkhead mount (DCB) configuration
Ordering Information
Available Part Numbers
Standard Performance | High Performance |
|
|
15DCB6 | 15DCB6B | 15DCB6BF | 15DCB10BF |
30DCB6 | 30DCB6B | 30DCB6BF | 30DCB10BF |
60DCB6 | 60DCB6B | 60DCB6BF | 60DCB10BF |
100DCB6 | 100DCB6B | 100DCB6BF | 100DCB10BF |
125DCB6 | 125DCB6B | 125DCB6BF | 125DCB6BF |
15DCF6 | 15DCF6B | 15DCB6F | 15DCB10F |
30DCF6 | 30DCF6B | 30DCB6F | 30DCB10F |
60DCF6 | 60DCF6B | 60DCB6F | 60DCB10F |
100DCF6 | 100DCF6B | 100DCB6F | 100DCB10F |
125DCF6 | 125DCF6B | 125DCB6F | 125DCB10F |
15DCB10 | 15DCB10B | | |
30DCB10 | 30DCB10B | | |
60DCB10 | 60DCB10B | | |
100DCB10 | 100DCB10B | | |
125DCB10 | 125DCB10B | | |
15DCF10 | 15DCF10B | | |
30DCF10 | 30DCF10B | | |
60DCF10 | 60DCF10B | | |
100DCF10 | 100DCF10B | | |
125DCF10 | 125DCF10B | | |
Specifications
Hipot rating (oneminute): |
| Line to Ground | 2250 VDC |
| Line to Line | 1450 VDC |
| | |
Operating Voltage(max.): | 80 VDC |
| | |
Rated Current: | 15A to 125A |
|
|
Operating Ambient Temperature Range(at rated current Ir): |
| -10°C to +55°C |
In an ambienttemperature (Ta) higher than +55°C the maximum operating current (Io) is calculated as follows: Io = Ir √(85-Ta)/30 |
Electrical Schematics
Standard Performance Versions
High Performance Versions (F & BF Styles)
Note 1: Depicts redundant style 6 terminals.
Note 2: Depicts optional circuit breaker.
Note 3: For 100 & 125A versions delete second coil.
Note 4: Depicts style 10 terminal versions which have separate ground stud.
Style 6 (15, 30 & 60 Amp) - Supplied with #10-32redundant studs
- 0.625 [15.88]spacing like polarity
- 0.750 [19.05]spacing opposing polarity.
- Torque Spec: 27 ±3 in. lb.
| Style 6 (100 & 125 Amp) - 1/4-20 redundant studs
- 0.750 [19.05]spacing like polarity,
- 1.0 [25.4]spacing opposing polarity.
- Torque Spec: 45 ±2 in. lb.
|
Style 10 (15 & 30 Amp) - PHOENIX CONTACT* p/nVDFK4
- Accepts 12 AWG stranded wire
- Wire strip length: 0.315 [8.0]
- Torque Spec.: 5.5 - 7.0 in.lb.
- Ground Stud: 8-32
| Style 10 (60 Amp) - PHOENIX CONTACT* p/nHDFK 16-VP
- Accepts 6 AWG stranded wire
- Wire strip length: 0.630 [16.0]
- Torque Spec.: 17.7 - 21.2in. lb.
- Ground Stud: 10-32
|
Style 10 (100 Amp) - PHOENIX CONTACT* p/nHDFK 25-VP
- Accepts 4 AWG stranded wire
- Wire strip length: 0.748 [19.0]
- Torque Spec.: 35.4 - 39.9in. lb.
- Ground Stud: 1/4-20
| Style 10 (125 Amp) - PHOENIX CONTACT* p/nHDFK 50-VP
- Accepts 1 AWG stranded wire
- Wire strip length: 0.945 [24.0]
- Torque Spec.: 35.4 - 39.9in. lb.
- Ground Stud: 1/4-20
|
*PHOENIX CONTACT is atrademark of Phoenix Contact GmbH & Co. KG. |
Case Styles
DCB6 & DCB6B
DCF6
Typical Dimensions: |
| Mounting Slots (4): | 260 x .39 [6.6 x 9.9 ] 60 to 125A versions |
| Mounting Holes (4) | .203 x .156 [5.2 x 4.0] 15 & 30A versions |
DCF6B
Typical Dimensions: |
| Mounting Slots (4): | 260 x .39 [6.6 x 9.9 ] |
DCB10 & DCB10B (15 & 30A)
DCB10 & DCB10B (60 to 125A)
DCF10 (15 & 30A)
Typical Dimensions: |
| Mounting Holes (4) | .203 x .156 [5.2 x 4.0] |
DCF10 (60 to 125A)
Typical Dimensions: |
| Mounting Slots (4): | 260 x .39 [6.6 x 9.9 ] |
DCF10B (15 & 30A)
Typical Dimensions: |
| Mounting Slots (4): | 260 x .39 [6.6 x 9.9 ] |
DCF10B (60 to 125A)
Typical Dimensions: |
| Mounting Slots (4): | 260 x .39 [6.6 x 9.9 ] |
Didn't find what you're looking for?
Post Buying Lead or contact
HiSupplier Customer Service Center
for help!
Related Search