Corcom 15ERK1 TE 2-1609089-6
Payment Terms: |
T/T,L/C,D/A |
Place of Origin: |
Shanghai, China (Mainland) |
Product Detail
Model No.:
15ERK1
Production Capacity:
12345678
Delivery Date:
35days
Means of Transport:
Ocean,Land,Air
Packing:
120PIECE/BOX
Brand Name:
TE
RK Series
Compact
Single stage
Chassis mount
Significant differential mode performance
Suitable for industrial machinery
Low input leakage
RK Series
- Compact
- Single stage
- Chassis mount
- Significant differential mode performance
- Suitable for industrial machinery
- Low input leakage current makes it suitable for portable equipment
Ordering Information
Specifications
Maximum leakage current, each Line to Ground: |
| @ 120 VAC 60 Hz | 0.16mA |
| @ 250 VAC 50 Hz | 0.26mA |
|
Hipot rating (one minute): |
| Line to Ground | 2250 VDC |
| Line to Line | 1450 VDC |
| | |
Operating Frequency: | 50 / 60 Hz |
| | |
Rated voltage (max.): | 250 VAC |
| | |
Rated Current: | 3A to 20A |
| |
Operating Ambient Temperature Range (at rated current Ir): |
| | -10°C to +40°C |
In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir √(85-Ta)/45 |
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
3ERK1 | 6ERK1 |
10ERK1 | 15ERK1 |
20ERK1 | |
Electrical Schematic
Case Styles
RK1 (3 & 6A)
Typical Dimensions: |
| Line/Load Terminals(4): | .250 [6.3] with .07 [1.8] Dia. hole |
| Ground Terminal(1): | .250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
| Mounting Holes (2): | .188 [4.75] Dia. |
RK1 (10, 15 & 20A)
Typical Dimensions: |
| Line/Load Terminals(4): | .250 [6.3] with .07 [1.8] Dia. hole |
| Ground Terminal(1): | .250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
| Mounting Holes (2): | .188 [4.75] Dia. |
Case Dimensions
Part No. | A | B | C | D | E |
(max.) | (max.) | (max.) | ± .015 ‡ | (max.) |
± .38 |
3ERK1 | 3.35 | 1.82 | 1.16 | 2.38 | 2.78 |
85.09 | 46.26 | 29.46 | 74.68 | 70.61 |
6ERK1 | 3.35 | 1.82 | 1.28 | 2.38 | 2.78 |
85.09 | 46.23 | 32.51 | 74.68 | 70.61 |
10ERK1 15ERK1 20ERK1 | 3.85 | 2.07 | 1.78 | 2.94 | 3.35 |
97.79 | 52.58 | 45.21 | 74.67 | 85.09 |
Minimum Insertion Loss in dB: |
Measured in closed 50 ohm system |
| | |
Common Mode / Asymmetrical (Line to Ground) | | Differential Mode / Symmetrical (Line to Line) |
| |
|
Current Rating | Frequency - MHz | .05 | .10 | .15 | .5 | 1 | 2 | 5 | 10 | 20 | 30 |
| 3A | 21 | 27 | 30 | 43 | 49 | 50 | 50 | 48 | 50 | 49 | 6A | 19 | 25 | 29 | 37 | 43 | 44 | 48 | 46 | 50 | 48 | 10A | 20 | 27 | 31 | 45 | 45 | 44 | 46 | 47 | 53 | 44 | 15A | 21 | 28 | 31 | 45 | 43 | 41 | 42 | 42 | 47 | 57 | 20A | 19 | 25 | 29 | 34 | 36 | 38 | 40 | 41 | 43 | 52 |
|
| | Current Rating | Frequency - MHz | .05 | .10 | .15 | .50 | 1 | 2 | 5 | 10 | 20 | 30 |
| 3A | 9 | 20 | 35 | 67 | 78 | 78 | 72 | 66 | 61 | 60 | 6A | 14 | 14 | 13 | 59 | 74 | 80 | 72 | 68 | 61 | 60 | 10A | 14 | 12 | 30 | 65 | 80 | 84 | 78 | 70 | 60 | 50 | 15A | 15 | 13 | 20 | 61 | 76 | 88 | 70 | 72 | 64 | 50 | 20A | 16 | 19 | 16 | 54 | 74 | 90 | 74 | 67 | 61 | 54 |
|
|